SG Series Programming Ethernet Configuration and Remote Programming
M550129-03 Rev G 5-21
5.5.3 SETTINGS
The Settings page is available to users who have FULL, Read/Write or Read
Only access to at least one power supply (Read Only users can make no
changes to the settings). In this page you will see continuous updates (2-5
times per second) of the actual voltage output (value displayed on the left)
and the actual live current output (value displayed to the right).
Figure 5-14. Settings Page
Voltage: value above is updated with actual voltage output of the power
supply
Current: value above is updated with actual live current output
Set V: the programmed voltage setting
Set I: the programmed current setting
Set OVP: the programmed over voltage protection setting
APPLY: puts into effect the newly input settings
CC and CV indicators: presently operating output mode of the power
supply, either constant voltage or constant current.
OVP indicator: highlighted red if over voltage protection is activated